ET-YW-202 Thermo-Hygrometer Display Instrument
| Previous | 1 / 7 | Next |
DESCRIPTION
ET-YW-202 is an instrument for measuring environmental temperature and humidity. It adopts industrial grade sensor chip, has the function of temperature and humidity detection, and can accurately collect indoor temperature and humidity. It can be applied to factory workshop, laboratory, greenhouse planting, industrial production, home furnishing and other fields.
ET-YW-202 can freely set the upper and lower limits of temperature and humidity alarm, and when the value exceeds the set alarm value, the instrument will send out the alarm sound to prompt the user; the sensor of the instrument is equipped with an independent cavity, which is not affected by the heating of the surrounding electronic components, and the measurement accuracy is higher and more accurate.
ET-YW-202 is equipped with induction holes around the back, so that the air can more widely contact with the internal induction plate, and the induction is more sensitive. In addition, the instrument can be set by temperature and humidity calibration, repeated testing to ensure that the value is more accurate.
FEATURES:
- USB supply electricity
- Temperature and humidity double detection
- Upper and lower limit alarm prompt
- High definition large screen display
- Time display
- High precision sensor
- External probe available
- Support user calibration
APPLICATIONS:
- Factory workshop
- Laboratory
- Greenhouse planting
- Drugstore
- Keep grain
- Plant
- Pharmaceuticals
NOTES:
- Operation of the instrument correctly and use it under the conditions specified in the technical parameter table.
- Please dispose of the waste in accordance with the relevant regulations of the national environmental protection.
- Avoid sun exposure.
- Avoid direct contact with corrosive chemicals.
WARNING:
- No private disassembly!
- Strictly prevent strong electricity, electrostatic impact!
SPECIFICATIONS:
| Type | ET-YW-202 |
| Temperature Range |
Built-in probe: -40~80¡æ External probe: -40~125¡æ (ET-YW-202X) |
| Humidity Range | 0~99.9%RH (Uncondensed) |
| Operational Environment | -40~80¡æ, ≤80%RH |
| Accuracy |
Temperature:
|
| Resolution |
Temperature:
|
| Refresh Interval | 2 times/second |
| Alarm Prompt | Audible Sound Alarm |
| Storage Environment | -10~60¡æ, ≤80%RH |
| Protection Level | IP20 |
| Power Supply | 5V direct plug into the external power supply; DC 5V/2A |
| Dimensions | 281 x 215 x 25mm |