Data logger for 3 current inputs 0-20mA and 1 two-state input

Previous 23 / 285 Next


Technical data

Value
Measured value Current
Two-state signal
CURRENT INPUT  
Measuring range 0 to 20 mA DC
Resolution better than 1 µA
Accuracy ±20 µA
Input resistance approx. 100 Ω
Minimum current 0 mA (open circuit)
Maximum current limited to approx. 40 mA
BINARY INPUT  
Parameters of the voltage contact „L“ level input voltage:< 0,8 V(*);
„H“ level input voltage:> 2 V;
Minimum voltage applicable:0 V;
Maximum voltage applicable:+30 V DC
Parameters of the voltage-free contact Contact resistance in „switched-on“ state:< 10 kOhm;
Contact resistance in the „switched-off“ state:> 2 MOhm;
Contact voltage in the „switched-off“ state:ca 3 V;
Minimum state duration necessary for latching the state:1s
GENERAL TECHNICAL DATA  
Operating temperature -20 to +60 °C
Channels 3x current input, 1x binary input
Memory 500,000 values in noncyclic logging mode; 350,000 values in cyclic record mode
Recording interval adjustable from 1 s to 24 h
Display and alarm refresh adjustable 1 s, 10 s, 1 min
Recording mode noncyclic - data logging stops after filling the memory
cyclic - after filling memory oldest data is overwritten by new
Real time clock year, leap year, month, day, hour, minute, second
Power Lithium battery 3.6V, size AA
Protection class IP20
Dimensions 61 x 93 x 32 mm
Weight (including batteries) approx. 120 g
Warranty 3 years