Theta AR200-FD ULTRASONIC ANENOMETER
| Previous | 19 / 20 | Next |
DESCRIPTION
AR200-FD is a robust, reliable ultrasonic anemometer which provides surface wind direction and wind speed measurement.It meets WMO CIMO Guide (WMO-No.8) requirements.
Data output through serial or analogue interfaces provides compatibility with DCS and PLC systems.
Standard 24V@5A heater ensures reliable operation even in harsh environmental conditions.
FEATURES
- IP66
- Aluminum alloy with teflon coating
- Designed for wind power industry, robust & durable
- 2 versions available: range 75m/s or 60m/s
- Heating function: 5A@24VDC
- Analog output is built in (optional to remove at order)
TECHNICAL DATA
| Wind Speed | |
| Principle | Ultrasonic |
| Measurement Range | 0 … 60m/s; 0 … 75m/s |
| Accuracy | 0-60 m/s: ±0.3 m/s or 3% of reading, whichever is greater; 60-75 m/s: 5% of reading |
| Resolution | 0.1m/s |
| Wind Direction | |
| Principle | Ultrasonic |
| Measurement Range | 0 … 360.0° |
| Accuracy | ±3° |
| Resolution | 0.1° |
GENERAL INFORMATION
| IP Class | IP66 |
| Dimensions(HxΦ) | 185 mm x 160 mm |
| Weight | 1.2Kg |
| Analog Outputs | 4 … 20 mA or 1 … 5V |
| Interface Default |
RS-485 RS232/SDI-12/RS422 (Configurable at Factory on Order) |
| Protocol Default |
THETA ASCII Modbus-rtu/SDI-12/NMEA-0183 (Configurable at Factory on Order) |
| Power |
15mA @12V DC (UNHEATED) 5A @ 24VDC (HEATED) |
| Operating Voltage-No Heating | 12 … 30VDC |
| Operating Temperature | -40 … £«80¡æ |
| Operating Humidity | 0 … 100%RH |
| Connector | 8 Pin |
| Cable | PUR 5m(Default) |