Excel Test Sdn Bhd
Sales & Admin Department
Unit C3A10, 3Ath Floor,
Block C, Kelana Square,
17, Jalan SS 7/26,
47301 Petaling Jaya,
Selangor, Malaysia.
Calibration Laboratory
Unit C717, 7th Floor,
Block C, Kelana Square,
17, Jalan SS 7/26,
47301 Petaling Jaya,
Selangor, Malaysia.
+603-7804 6186
+603-7804 4186
ychooimy
Theta AR200P ULTRASONIC ANENOMETER
| Previous | 18 / 20 | Next |
DESCRIPTION
AR200P is a robust, reliable ultrasonic anemometer that provides surface wind direction and wind speed measurement.It meets WMO CIMO Guide (WMO-No.8) requirements.
All made of stainless steel 316L.
Standard 24V@5A heater ensures reliable operation even in harsh environmental conditions.
TECHNICAL DATA
| Wind Speed | |
| Principle | Ultrasonic |
| Measurement Range | 0 … 60m/s; 0 … 75m/s |
| Accuracy | 0-60 m/s: ±0.2 m/s or 2% of reading, whichever is greater; 60-75 m/s: 4% of reading |
| Resolution | 0.1m/s |
| Wind Direction | |
| Principle | Ultrasonic |
| Measurement Range | 0 … 360.0° |
| Accuracy | ±2° |
| Resolution | 0.1° |
GENERAL INFORMATION
| IP Class | IP66 |
| Dimensions(HxΦ) | 327 mm x 256 mm |
| Weight | 2Kg |
| Analog Outputs | 4 … 20 mA or 1 … 5V |
| Interface Default |
RS-485 RS232/SDI-12/RS422 (Configurable at Factory on Order) |
| Protocol Default |
THETA ASCII Modbus-rtu/SDI-12/NMEA-0183 (Configurable at Factory on Order) |
| Power |
8mA @12V DC (UNHEATED) 5A @ 24VDC (HEATED) |
| Operating Voltage-No Heating | 12 … 30VDC |
| Operating Temperature | -40 … £«80¡æ |
| Operating Humidity | 0 … 100%RH |
| Connector | 8 Pin |
| Cable | PUR 5m(Default) |


