Excel Test Sdn Bhd
Sales & Admin Department
Unit C3A10, 3Ath Floor,
Block C, Kelana Square,
17, Jalan SS 7/26,
47301 Petaling Jaya,
Selangor, Malaysia.
Calibration Laboratory
Unit C717, 7th Floor,
Block C, Kelana Square,
17, Jalan SS 7/26,
47301 Petaling Jaya,
Selangor, Malaysia.
Latest News
Body Temperature Thermal Scanner For Precautionary Measures From COVID-19 Outbreak
Mar 17, 2020There are only 2 types of products able to detect human body inner temperature which are Medical Infrared Thermometer & Thermal Imaging Camera. Mostly people mixing Medical Infrared Thermometer & General Infrared Thermometer has the same accuracy as what doctors are using in clinic/hospital.
Honestly we can tell is General Infrared Thermometer is not design to detect human body temperature. A good start would be comparing this General Infrared Thermometer with a dedicated one and do not expect the temperature accuracy can within ± 1 ¡æ as Medical Infrared Thermometer. A difference of more than ± 1 ¡æ is to be expected which is lot when checking for fever.
Thus, we are offering the hiighest accuracy (<± 0.3 ¡æ or <± 0.6 ¡æ) for Thermal Imaging Camera, 12X better for temperature accuracy compare with others which only able to get ± 2 ¡æ temperature accuracy. Not only that, We are 2X affordable in the market to give a hand to corporate/universities/hospital/hospitality & government.
- Precise Measurement (< +0.6C)
- Rapid/Fast respond measurement (Frame rate 50/60Hz)
- Fever temperature detection & alarm (High-Temperature Alarm Mark & Buzzer)
- Stable & Reliable continuous measurement (Due to stable internal temperature reference-auto calibration)
Online Human Body Temperature Thermal Scanner
Mar 17, 2020Full screen measurement, real-time highest temp auto tracking, multiple high temp target alarming.
Resolution: 384x228 (Thermal Camera),
Resolution: 1920x1080 (Visible Camera),
Temperature measurement accuracy: <± 0.3 ¡æ
Warning! BECARE FULL!
DON't buy *Industrial Thermal Imaging Camera or Low quality Camera for Human Body Temperature Monitoring.
WHY?
Because you need;
1. Measurement accuracy +0.6degC or better Thermal Imaging Camera. Industrial & low quality Camera accuracy is + 2~3DegC
2. Camera designed & calibrated for ''Human Skin'' emissivity.
3. With internal or External stable Calibration Blackbody temperature reference
4. Design for continuosly monitoring
TE-W300 Handheld body temperature Thermal Imaging Camera
Mar 17, 2020
TE-W300 Handheld body temperature rapid screening instrument
¡ôTemperature measurement accuracy of up to 0.6¡æ
¡ôInfrared image fusion,direct temperature measurement in the visible image
¡ôReal-time video,all of the testing process are documented
¡ôRugged and easy to operate,2m drop resistant
¡ôDedicated video management software,always check the record,professional analysis software
Warning! BECARE FULL!
WHY?
Because you need;
1. Measurement accuracy +0.6degC or better Thermal Imaging Camera. Industrial & low quality Camera accuracy is + 2~3DegC
2. Camera designed & calibrated for ''Human Skin'' emissivity.
3. With internal or External stable Calibration Blackbody temperature reference
4. Design for continuosly monitoring
What Is Temperature Calibration?
Mar 17, 2020In the industrial practise, the temperature calibration is to make sure the temperature sensor is within the calibration tolerances. If a temperature sensor is found to be out of tolerance, it is typically and recommended to replaced a new temperature sensor or new unit.
You might be curious how we can get to know that the temperature sensor is ‘In-Tolerance’ or ‘Out-of-Tolerance’ after completed temperature calibration? So, there are 2 common ways to determine which are Unit Correction Value & Measurement Uncertainty based on calibration certificate results.
First of all, we determine the ‘Tolerance’ based on Unit Correction Value. We look for the temperature accuracy from the unit specification and compare with the calibration results. Based on Diagram 1.0, Let’s say If the unit specification accuracy is +/- 0.5°C, the correction value read in calibration certificate is +/- 0.35°C. Thus, it is ‘In-Tolerance’ or fit to use. If correction value read in calibration certificate is +/- 0.65°C, it is consider as ‘Out-of-Tolerance’ or not fit to use.
Besides, the another way to determine the ‘Tolerance’ is based on Measurement Uncertainty. The measurement uncertainty is the combination of all or most of the possible sources of errors that the unit can receive or encouter. Thus, we use the measurement uncertainty as the basis for tolerance. Since the measurement uncertainty is usually very small and will result in a strict tolerance, the possibility of a failed result is higher.
Data Logger Subscription
Mar 17, 2020Data Logger Subscription
Why Subscribe with Excel Test?There are few reasons that subscription make sense. Here are some benefits;
- One-Time Payment
- C/W Accredited Calibration Certificate
- No Long-term lock-ins
- Battery Replacement
- Faulty Unit Replacement
- New Data Logger Every 3 Years
This subscription plan is highly recommended for those companies who required to have a data logger, thermometer or thermo-hygrometer required calibration every year.